ALT-300(F)
AC voltage testers
The ALT 300(F) was primarily designed for testing bucket truck booms and liners per the ANSI 92.2 standard. However, its continuously adjustable dual output voltages, high power rating, and mobility also make it ideal for field testing other high capacitance loads requiring AC withstand testing. This unit is also used for overvoltage AC withstand testing of ISO phase bus, switchgear, circuit breakers, reclosers, vacuum bottles, and hot sticks.
Features:
- Secondary connected 2 Range Voltmeter: 120/300kV
- 2 Range Current Meter: 0-250uA and 0-1.0mA with x1, x10, x100 multipliers up to 100 mA
- 19 inch rack benchtop style control
- Fixed overload set to 120% of variable transformer rated output current
- Transit protected meters prevent meter damage between test sites
- Guard/Ground circuit for accurate leakage current measurement
- Zero Start and External safety Interlock provisions
Specifications
Input: | 230 V, 50/60 Hz, 30 A |
---|---|
Output: | 300kV AC, 7kVA resistive load 7kVA capacitive load Output current is reduced at lower voltages |
Duty: | 7kVA: 1 hour ON, 2 hour OFF 5 kVA: continuous |
Voltmeter: | 3.5”, scaled 120/300kV kV AC, ±2% F.S. |
Current Meter: | 3.5”, scaled 0-250uA and 0-1.0mA ±2% F.S. with rangemultipliers of x1, x10, x100 up to 100 mA |
Distortion: | Less than 5% |
Size and Weight: (W x D x H) |
Control: 21 x 15.5 x 15.25 in., 80 lb. 534 x 394 x 387 mm, 36 kg HV Tank: 28 x 28 x 69 in., 1050 lb. 712 x 712 x 1753 mm, 476 kg |
Output Termination: | Top toroid |
Scope of Supply: | 20ft black ground lead, 20ft shielded return cable, external interlock plug, operations manual, calibration certificateALT Series: Other models are available from 100 kVac – 300 kVac, 7.2 kVA |