Product Overview
The VCL-2145-SSU, is specifically designed to provide reliable and high precision synchronization in 2G, 3G, HetNet and LTE mobile telecommunications networks as well as backhaul wire-line SDH / SONET and Synchronous Ethernet networks. It may be also used by Railways, Airports (and Air-Traffic Control), Power Generation and Distribution companies and other Utility companies who require fail-safe, high-reliability and precise synchronized synchronization outputs that are concurrently locked to GNSS (GPS/GLONASS) References.
Fully Reliable / Redundant Equipment, High Performance Network

The VCL-2145-SSU accepts a wide range of input and outputs. Output capabilities allow it to support legacy frequency timing applications, including E1/ T1, 10 MHz, 1 PPS (PPS) as well as Time-Of-Day (ToD) using redundant Input / Output Clock cards. Additionally, the SSU may also be used to provide IEEE-1588v2 PTP Grandmaster and NTP Outputs. Optional interfaces include IEEE-1588v2 PTP Grandmaster and NTP Outputs.
VCL-2145-SSU provides protection that is superior to “network redundancy” which must re-acquire synchronization from a different Clock Equipment located elsewhere in the network.
. PTP Grandmaster is Modular and compact 6U, 19” or ETSI rack mountable equipment to provide network synchronization
. Fully integrated – IEEE 1588 (2008) v2 PTP server and NTP Server
. High capacity (up to 16,384 PTP slaves / clients) per chassis.
. Compliant with ITU-T Telecom Profile G8265.1 and G8275.1
. High PTP message rate (up to 128 messages per second)
. Single or dual GNSS (GPS) inputs with Stratum 1
. Single platform for traditional TDM, PTP, NTP and SyncE
. Integrated with Next Generation Networks synchronization
. Time-of Day Server
. Timing sources for Sync-E, Ethernet Network Equipment
. OCXO and Rubidium (RbXO) Holdover clock options
. Protection / Redundancy: Module protection for all critical functions (Inputs, Holdover Clock, Outputs, Power)
. Fully manageable Local and Remote Graphical User Interface (Omni View)
- VCL-2145-SSU hardware design is intended to integrate intelligent, functional modules into a flexible, fully protected / fully redundant system to seamlessly satisfy current and future customer requirements to provide Phase, frequency time synchronization over packet based networks.
- VCL-2145-SSU integrated up to 6 high performance modules enabling a total capacity of more than 6,000 PTP slave clients. Each module integrated with PTP Engine with accurate time stamping and supports 1024 PTP Clients each card.
- Automatic Redundant configuration: If a primary card/module is installed in a slot, the new secondary card/module will be automatically configured to the same settings, as the primary card/module.
- Input signals from GNSS (GPS/GLONASS) are by-passed / switched / passed-through in case of any function / card level failure.
. Protected 1:1 / 1+1 Antenna (Redundant)
. Antenna Type: Active
. N-Type (F) Connector
. Frequency: GPS L1 and L2 Bands (1.575 MHz); GLONASS: 1602-1615MHz
. Amplifier Gain: Typically +/-40dB (GPS L1 band); +/-34 (GLONAAS band)
. Reverse Polarity Protection
. Lightening Protection: According to EN61000-4-5 Level 4.
. Operating temperature: -40°C to +85°C
. Operational: -40°C to +85°C
. Storage: -40°C to +85°C
. Humidity: 95 % non-condensing
. Salt and Fog: Mil. Std. 202F, Method 101D Cond. B
. Lightning Protection: According to EN61000-4-5 Level 4
. Suitable for outdoor and rooftop installations.
. (Note: cables and connectors are not included and must be ordered separately as optional extras).
. Cable Type: LMR 400 or equivalent with N connector
. Total Cable Length:
. 30, 50, 60, 90 meters LMR 400
. 91 to 120 meters (LMR400 with one active in-line amplifier).
. 121 to 240 meters (LMR 600 with two active in-line amplifiers).
IEC – EMC Certified to EN 55022: 2005 / CISPR 22, EN 55024:2005, IEC 61000 4-2
CE – 2001/95/EC, 2006/95/EC, EN60950-1, EN61000-6-2, EN61000-6-4
FCC – FCC Part 15 B Class A: Conducted Emission test on Power Line
FCC Part 15 B Class A: Radiated Emission >1 GHz FCC, 6 GHz, on Power Line
. Dual Redundant – maximum output / power supply card: 200W
. 1+1 AC power (100 to 240V AC, 50/60 Hz)
. 1+1 DC 24V power
. 1+1 DC -48V power
. AC or DC